blob: 4e128af78397726025226435e1f50e8c05b884d5 (
plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
|
# Copyright 1999-2021 Gentoo Authors
# Distributed under the terms of the GNU General Public License v2
EAPI="7"
inherit linux-info flag-o-matic systemd udev tmpfiles
DESCRIPTION="APC UPS daemon with integrated tcp/ip remote shutdown"
HOMEPAGE="http://www.apcupsd.org/"
SRC_URI="mirror://sourceforge/apcupsd/${P}.tar.gz"
LICENSE="GPL-2"
SLOT="0"
KEYWORDS="amd64 ~arm ~ppc ~x86"
IUSE="snmp +usb +modbus cgi gnome kernel_linux"
DEPEND=">=sys-apps/util-linux-2.23[tty-helpers(-)]
cgi? ( >=media-libs/gd-1.8.4 )
modbus? ( usb? ( virtual/libusb:0 ) )
gnome? (
>=x11-libs/gtk+-2.4.0:2
dev-libs/glib:2
>=gnome-base/gconf-2.0
)
snmp? ( >=net-analyzer/net-snmp-5.7.2 )"
RDEPEND="${DEPEND}
virtual/mailx"
CONFIG_CHECK="~USB_HIDDEV ~HIDRAW"
ERROR_USB_HIDDEV="CONFIG_USB_HIDDEV: needed to access USB-attached UPSes"
ERROR_HIDRAW="CONFIG_HIDRAW: needed to access USB-attached UPSes"
DOCS=( ChangeLog ReleaseNotes )
HTML_DOCS=( doc/manual )
PATCHES=(
"${FILESDIR}"/${PN}-3.14.9-aliasing.patch
"${FILESDIR}"/${PN}-3.14.9-close-on-exec.patch
"${FILESDIR}"/${PN}-3.14.9-commfailure.patch
"${FILESDIR}"/${PN}-3.14.9-fix-nologin.patch
"${FILESDIR}"/${PN}-3.14.9-gapcmon.patch
"${FILESDIR}"/${PN}-3.14.9-wall-on-mounted-usr.patch
)
pkg_setup() {
if use kernel_linux && use usb && linux_config_exists ; then
check_extra_config
fi
}
src_configure() {
local myconf
use cgi && myconf="${myconf} --enable-cgi --with-cgi-bin=/usr/libexec/${PN}/cgi-bin"
if use usb ; then
myconf="${myconf} --with-upstype=usb --with-upscable=usb --enable-usb --with-dev="
use modbus && myconf="${myconf} --enable-modbus-usb"
else
myconf="${myconf} --with-upstype=apcsmart --with-upscable=smart --disable-usb"
use modbus || myconf="${myconf} --disable-modbus"
fi
# We force the DISTNAME to gentoo so it will use gentoo's layout also
# when installed on non-linux systems.
econf \
--sbindir=/sbin \
--sysconfdir=/etc/apcupsd \
--with-pwrfail-dir=/etc/apcupsd \
--with-lock-dir=/run/apcupsd \
--with-pid-dir=/run/apcupsd \
--with-log-dir=/var/log \
--with-nis-port=3551 \
--enable-net --enable-pcnet \
--with-distname=gentoo \
$(use_enable snmp) \
$(use_enable gnome gapcmon) \
${myconf} \
APCUPSD_MAIL=$(type -p mail)
}
src_compile() {
# Workaround for bug #280674; upstream should really just provide
# the text files in the distribution, but I wouldn't count on them
# doing that anytime soon.
MANPAGER=$(type -p cat) \
emake VERBOSE=2
}
src_install() {
emake DESTDIR="${D}" VERBOSE=2 install
rm "${ED}"/etc/init.d/halt || die
insinto /etc/apcupsd
newins examples/safe.apccontrol safe.apccontrol
doins "${FILESDIR}"/apcupsd.conf
doman doc/*.8 doc/*.5
einstalldocs
rm "${ED}"/etc/init.d/apcupsd || die
newinitd "${FILESDIR}/${PN}.init" "${PN}"
newinitd "${FILESDIR}/${PN}.powerfail.init" "${PN}".powerfail
systemd_dounit "${FILESDIR}"/${PN}.service
dotmpfiles "${FILESDIR}"/${PN}-tmpfiles.conf
# remove hal settings, we don't really want to have it still around.
rm -r "${D}"/usr/share/hal || die
# replace it with our udev rules if we're in Linux
if use kernel_linux ; then
udev_newrules "${FILESDIR}"/apcupsd-udev.rules 60-${PN}.rules
fi
}
pkg_postinst() {
tmpfiles_process ${PN}-tmpfiles.conf
if use cgi ; then
elog "The cgi-bin directory for ${PN} is /usr/libexec/${PN}/cgi-bin."
elog "Set up your ScriptAlias or symbolic links accordingly."
fi
elog ""
elog "Since version 3.14.0 you can use multiple apcupsd instances to"
elog "control more than one UPS in a single box with openRC."
elog "To do this, create a link between /etc/init.d/apcupsd to a new"
elog "/etc/init.d/apcupsd.something, and it will then load the"
elog "configuration file at /etc/apcupsd/something.conf."
elog ""
elog 'If you want apcupsd to power off your UPS when it'
elog 'shuts down your system in a power failure, you must'
elog 'add apcupsd.powerfail to your shutdown runlevel:'
elog ''
elog ' \e[01m rc-update add apcupsd.powerfail shutdown \e[0m'
elog ''
if use kernel_linux; then
elog "Starting from version 3.14.9-r1, ${PN} installs udev rules"
elog "for persistent device naming. If you have multiple UPS"
elog "connected to the machine, you can point them to the devices"
elog "in /dev/apcups/by-id directory."
fi
}
|